Type | Read/write | Author | Availability |
Data provider | Write | FINBOURNE | Provided with LUSID |
Providing you have sufficient access control permissions, the Notification.ManualEvent.Writer
provider enables you to write a Luminesce SQL query that triggers one or more manual events in LUSID's Notification Service.
You must construct a valid table of data to write, one manual event per record. Notification.ManualEvent.Writer
lists the fields (columns) available to populate with values for each record, and has a set of parameters to help you construct a valid table.
See also: Notification.Subscription
Basic usage
@table_of_data = <select-statement>;
select * from Notification.ManualEvent.Writer where toWrite = @table_of_data;
Query parameters
Notification.ManualEvent.Writer
has parameters that help you construct a valid table of data to write.
Note: The ToWrite
parameter is mandatory and describes the data for the manual events you are triggering.
To list available parameters, their data types, default values, and an explanation for each, run the following query using a suitable tool:
select FieldName, DataType, ParamDefaultValue, Description from Sys.Field where TableName = 'Notification.ManualEvent.Writer' and FieldType = 'Parameter';
Data fields
Notification.ManualEvent.Writer
lists the fields you can populate in your table of data to write.
The following fields are mandatory to include in the table of data:
Message
Subject
To list all available fields, their data types, whether fields are considered 'main', and an explanation for each, run the following query using a suitable tool:
select FieldName, DataType, IsMain, IsPrimaryKey, SampleValues, Description from Sys.Field where TableName = 'Notification.ManualEvent.Writer' and FieldType = 'Column';
Write errors
We recommend examining the results of every write query using the WriteError
field.
For each record in the table of data, if unsuccessful, Notification.ManualEvent.Writer
returns a WriteError
message containing an error code and explanation to help you discover why LUSID considers the operation invalid.
Examples
Note: For more example Luminesce SQL queries, visit our Github repo.
Example 1: Trigger a manual event
@data_to_write = select 'A new corporate action has been announced' as Message, 'New Corporate Action Announced' as Subject, ' { "AnnouncementDate": "2023-02-13", "Company": "Apple", "CorporateAction": "Cash dividend" } ' as JsonMessage; select * from Notification.ManualEvent.Writer where ToWrite = @data_to_write;
Example 2: Trigger multiple manual events with the same subject and message
@@message = select 'A new corporate action has been announced'; @@subject = select 'New Corporate Action Announced'; @announcements = values ('{ "AnnouncementDate": "2023-02-15", "Company": "Microsoft", "CorporateAction": "Stock split" }'), ('{ "AnnouncementDate": "2023-02-17", "Company": "BP", "CorporateAction": "Reverse stock split" }'); @data_to_write = select @@message as Message, @@subject as Subject, column1 as JsonMessage from @announcements; select * from Notification.ManualEvent.Writer where ToWrite = @data_to_write;